Model X: A/C not cooling after a new condenser
In plain words
After another shop replaced the A/C condenser, the A/C would not cool. Sensors and other parts were replaced with no change. The new condenser itself was faulty, and an original-equipment condenser fixed it.
FOR A QUALIFIED TECHNICIAN (shop notes, as recorded)
Symptoms
After condenser replacement by another shop, A/C (air conditioning) not cooling, compressor not engaging. Multiple THC alerts (EXV (electronic expansion valve) out of position, chiller, pressure sensors). Thermal Performance Test failing on chiller and evaporator. Correct refrigerant charge verified (726g, no rear HVAC (heating, ventilation and air conditioning)). Sensors and chiller/EXV replaced with no change. Later THC_d0010_compressor appeared. Root cause was defective new condenser.
Alerts shown
THC_w0010_EXVOutOfPositionTHC_d0016_chillerTHC_d0011_PresSnsDisTHC_d0012_PressSnsSuctTHC_W0242_exvSelfErrorTHC_d0010_compressor
Safety: A/C refrigerant work needs certified recovery equipment. Leave it to a qualified technician.
Tests run
- Verified refrigerant charge 726g
- Replaced both PT sensors
- Replaced evaporator temperature sensor
- Replaced chiller and EXV assembly
- Checked 40A compressor fuse (good)
- Thermal Performance Tests failed until condenser replaced
Confirmed fix
Replaced defective new A/C condenser with OEM unit. A/C worked perfectly after that.