Independent repair resource. Not affiliated with or endorsed by Tesla, Inc.

Confirmed fix at S 3 X Y Auto Service

Model 3: A/C quits on longer drives

2018 Model 3 · Long Range · Climate/HVAC

In plain words

The A/C worked in the shop but stopped cooling on longer drives, and system tests failed. Replacing the evaporator temperature sensor fixed it, and the compressor stopped shutting off.

FOR A QUALIFIED TECHNICIAN (shop notes, as recorded)

Symptoms

A/C (air conditioning) works fine while vehicle is in the shop but fails (stops blowing cold) on longer drives. Radiator health shows 0% in Service Mode. HVAC (heating, ventilation and air conditioning) Performance Test FAIL (temperature never reached expected values). Thermal System Performance Test FAIL: refrigerant flow target through the chiller EXV (electronic expansion valve) was greater than expected (suggested low refrigerant charge).

Alerts shown

Tests run

Confirmed fix

Replaced evaporator temperature sensor (thermistor, PN (part number) 1107675-00-A or compatible). AC now functions normally on longer drives; compressor no longer inhibited.

Parts

Related cases

Want this checked? Book S 3 X Y Auto Service, Mission Viejo

Book S 3 X Y Auto Service Call (949) 741-7399